Items
|
|
Performance & Parameter
|
Main unit
|
Principle
|
Transit time ultrasonic flowmeter
|
Accuracy
|
± 1%
|
Display
|
2×20 character LCD with backlight, support the language of Chinese,
English and Italian
|
Signal Output
|
1 way 4-20mA output, electric resistance 0~1K, accuracy 0.1%
|
1 way OCT pulse output(Pulse width 6~1000ms, the default value is 200ms)
|
1 way relay output
|
Signal Input
|
3 way 4-20mA input, accuracy 0.1%, acquire signals such as temperature,
press and liquid level.
|
Achieve to heat measurement by connecting the temperature transducer PT100.
|
Data Interface
|
Insulate RS485 serial interface, upgrade the flowmeter software by computer,
support MODBUS
|
Data Record
|
Thermal printer, external SD card(2G of capacity)
|
Pipe Installation
Condition
|
Pipe Material
|
Steel, Stainless steel, Cast iron, Copper, Cement pipe, PVC, Aluminum,
Glass steel product, liner is allowed.
|
Pipe Diameter
|
15~6000mm
|
Straight Pipe
|
Transducer installation should be satisfied: upstream 10D, downstream 5D,
30D from the pump.
|
Measuring
Medium
|
Type of Liquid
|
Single liquid can transmit sound wave, such as water, sewage, oil, chemicals,
plant effluent, beverage, ultra-pure liquids, etc.
|
Temperature
|
-30~160°c
|
Turbidity
|
Less than 10000ppm and little bubble
|
Flowrate
|
0 ~ ±7m/s
|
Working
Environment
|
Temperature
|
main unit: -20~60°c; Transducer: -30~160°c
|
Humidity
|
main unit: 85%RH; Transducer protection level: IP67
|
Power Supply
|
8 built-in Ni-MH batteries 1.2V(for over 20 hours of operation). Could operate 8 hours
by connecting 4-20mA signal output. 90V - 260V AC adapter
|
Power Consumption
|
1.5W
|